15. settIng the boIler parameters

The boiler parameters may only be modified by professionally qualified staff proceeding as follows:
a) press the
, keys on the boiler's front panel together for about 3 s until the parameter H90 appears on
the display;
b) press the
keys to select the parameter for modification;
c) press the
and
keys to modify the parameter;
d) press the
key to ex­it the programming function.
The following are the parameters generally used:
n° parametro
Description
h90
Setting for domestic hot water reduced temperature (°C)
h91
D.H.W. (Domestic Hot Water) program
(0 = enabled; 1 = disabled)
h505
Max­imum temperature (°C) of the central heating circuit HC1 corresponding to:
- the main circuit in systems with just one zone;
- the circuit of the zone where the QAA73 temperature control device is installed in case of
systems with more than one high-temperature zone;
- the high temperature zone circuit in mix­ed systems and if the SIEMENS AGU2.500
accessory is used.
h507
Max­imum temperature (°C) of the central heating circuit HC2 of a system with more than one
zone, corresponding to the circuit of the low-temperature zone if the SIEMENS AGU2.500
accessory is used.
h516
Automatic Summer / Winter switching temperature (°C).
h532
Selection of temperature curve of central heating circuit HC1 (see Graph 1)
h533
Selection of temperature curve of central heating circuit HC2 (see Graph 1)
h536
Max­imum speed at max­imum output in heating mode (rpm - max­imum speed limitation)
h612
Setting value of required speed (rpm) at low-fire
h536-h613
Setting value of required speed (rpm) at high-fire heating / domestic hot water mode
h541-h610
PWM (%) setting: max­imum output in heating / domestic hot water mode
h544
Pump post-circulation time in central heating mode (min)
h545
Burner operating pause time between two start-ups (s)
h552
Hydraulic system setting (see instructions provided with the SIEMENS AGU2.500 accessory).
H552 = 50 with AGU2.500 and with QAA73 + zones with room thermostat
H552 = 80 with RVA 47
h553
Configuration of heating circuits
H553 = 12 with AGU2.500
h615
Programmable function
h632
Configuration of system with low loss header P1
H632 = 00001111 with AGU2.500 and with QAA73 + zones with room thermostat
H632 = 00001000 with storage tank without low loss header
The value of Bit could be 1 or 0.
Press the keys 5 and 6 to select the bit to modify (b0 is the bit on the right, b7 is the last bit
on the left).
To modify the Bit value press on the keys 7 and 8
h641
Fan post-purge interval (s)
h657
Setpoint of autonomous ANTILEGIONELLA function
60...80 °C = setting temperature range
table 4
If the electronic circuit board is replaced, make sure that the parameters set are those specific to the boiler
model, as indicated in the documentation available from the authorised Service Centre.
InstructIons pertaInInG to the InstaLLer
0 = function inactive
105
Factory setting
10
1
80
80
20
15
15
Refer to
paragraph 12.1
10
180
2
21
9
00001100
10
0