Herunterladen Inhalt Inhalt Diese Seite drucken

Installation - Waeco CoolMatic CD30 Montage- Und Bedienungsanleitung

Schubfach-kühlbox
Vorschau ausblenden Andere Handbücher für CoolMatic CD30:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
CD20, CD30
6

Installation

A
NOTICE!
 Ensure that the positive cable is connected to the positive ter-
minal and the negative cable to the negative terminal.
 When choosing the installation location, ensure that the air
heated by the liquefier can be drawn off.
I
NOTE
To avoid voltage loss and therefore a drop in performance, the
cable route should be kept as short as possible and should not
be interrupted if this is possible. For this reason avoid additional
switches, plug or power strips.
Please observe the following instructions:
 Determine the necessary cable cross section of the intake line using the
diagram below:
16
14
12
10
8
6
4
2
0
0
2
 Connect your cooling device as directly as possible to the battery terminal
or to an outlet with a fuse of at least 15 A (12 V) or 7.5 A (24 V).
 To screw the device in place use the screwing holes provided on the side
of the device (see fig. 4, page 4 and fig. 5, page 4).
 You can detach the compressor from the cooling device and mount it in
another place on the cooling device, or separately from it (fig. 2,
page 3). Make sure that the refrigerant line is 1.5 m (CD20)/1.5 m (CD30)
long.
EN
12 Volt devices
4
6
8
10
12
24 Volt devices
14
16
18
20
22
Installation
24
26
28
Metres of cable (m)
23

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Coolmatic cd20

Inhaltsverzeichnis