Herunterladen Inhalt Inhalt Diese Seite drucken

Assembling The Vacuum Cleaner; Installation And Connection - Oase BioCompact 50 Gebrauchsanleitung

Vorschau ausblenden Andere Handbücher für BioCompact 50:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Do not use in conjunction with chemicals,
foodstuff, easily flammable or explosive sub-
stances.
ASSEMBLING THE VACUUM
CLEANER
N O T E
Thoroughly rinse out all filter material
with warm tap water before using for the
first time in order to remove any soiling.
(→ Cleaning or replacing the filter media)
BioCompact 25
The supplied suction cups serve for fastening the
unit to a clean, smooth surface.
How to proceed:
 A
1. Remove the lid of the filter container.
2. Pull out the foam filter.
3. Pull off the motor housing.
4. Push the suction cups into the mounting holes
of the filter container and motor housing with
a twisting movement.
5. Reassemble the unit in the reverse order.
6. Adjust the flow at the flow regulator.
– To reduce the flow: Move the flow regula-
tor in the direction Min.
– To increase the flow: Move the flow regu-
lator in the direction Max.
7. Fit the water distributor.
BioCompact 50
How to proceed:
 B
1. Remove the lid of the filter container.
2. Pull out the foam holder.
3. Pull out the filter box.
4. Fill the empty chamber of the filter box with
filter medium.
5. Push the suction cups into the mounting holes
of the filter container with a twisting move-
ment.
6. Reassemble the unit in the reverse order.
7. Adjust the flow at the flow regulator.
– To reduce the flow: Move the flow regula-
tor in the direction Min.
– To increase the flow: Move the flow regu-
lator in the direction Max.
8. Fit the water distributor.

INSTALLATION AND CONNECTION

N O T E
Ensure that the pump never runs dry!
Possible consequences: The pump will be
destroyed.
- EN -
15

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Biocompact 25

Inhaltsverzeichnis