GB
overvIew
4.1
OPeRAtING eLeMeNtS AND DISPLAyS ON
DeVICe
1
Delivery volume controller 0-10
2
Selector switch for operating mode
3
Indicator light (Error)
4
Operating light (Power)
5
EMERGENCY STOP switch
6
Switch for activating remote control
POWER ERROR
4
3
5
2
Rear view
The delivery volume controller (Fig. 3, 1) is used to regulate
the convey capacity from 0-10 smoothly.
The remote control (available separately, art.
no. 2308 417) can be used to conveniently
control the pump's delivery volume from the
spray lance.
40
SPEED
1
ELEC
PNEUM
REMOTE
Control
Controler
6
The selector switch (Fig. 3, 2) offers the following modes:
"A" position = automatic
Basic setting for control with an automatic
A
spray lance, pneumatic spray lance or re-
mote control
"F" position = manual activation
Switches on the mortar spraying machine.
A
This setting is required for:
• disassembling the pump unit
When using the pneumatic lance, this set-
ting is also needed for:
• pre-rinsing the mortar hose to improve
the material's ability to slide
• cleaning
"R" position = reverse gear (must be held in
this position).
A
This setting is required for:
• relieving pressure on the mortar hose
• assembling the pump unit
Detailed explanation of selector switch use:
If the selector switch is in the "A" position, the PC830 can be
switched on and off with the material shut-off on the auto-
matic or pneumatic spray lance.
If there is no spray lance fitted (e.g.: assembly/disassembly the
pump unit ), the machine is switched on using the "F" switch
position and off using the "A" position.
Since the air supply through the compressor needs to be
switched off to clean the mortar hose, the pneumatic lance
is not controlled using the material shut-off. In this case, the
machine must therefore also be switched on using the "F" po-
sition.
Important: control via the selector switch and
material shut-off are treated equally.
The machine can be switched from the "A" po-
sition (control using material shut-off ) to "F" at
any time.
We would therefore recommend that only one
person operate the machine.
The operating light (green, Fig. 3, 4) indicates that the machine
is energised and ready.
The indicator light (red, Fig. 3, 3) indicates a fault. For detailed
information about this kind of fault, refer to the „Rectification
of faults" section on page 53.
The switch (Fig. 3, 6) allows you to switch between internal
and external control. In Position "I", the PC 830 is controlled
with the integrated control panel. In Position "II" it is controlled
with the remote control.