Herunterladen Inhalt Inhalt Diese Seite drucken

Installation; Maintenance - Gorenje IDKG 9545 E Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 18
ENG
HOOD INSTALLATION, MAINTENANCE AND USAGE
GENERAL INFORMATION
Before installing and/or using the hood, you should read all of the following instructions carefully. Before installing the hood, make sure that
the voltage (V) and frequency (Hz) given on the tag containing the serial number and technical data, which is placed inside the device,
corresponds to the voltage and frequency in the place of installation.

INSTALLATION

The hood cannot, under any circumstances, be connected to the ventilation ducts of devices powered by anything but electricity (bathroom
heaters, boilers, ovens).
The device cannot be installed on hob ovens.
CONNECTING TO ELECTRICITY
The hood must be installed in a stable and permanent manner. Connect the hood to electricity! To obtain further information concerning your
line's voltage and frequency, check the tag inside the device, carefully connect the cable to the plug or connect the device to a multi-pole
switch with at least 3-mm gaps between contacts. The hood's power supply cable (type H05 VV 3X0,75mm 2,2m), marked L (line) and N
(neutral) and fastened with a clamp, should be connected to an appropriate, permanent power supply by an authorised and certified person,
who has to install the hood according to any binding standards and regulations, using a multi-pole switch with at least 3-mm gaps between
contacts. Connect the power supply cable, if it has a plug, to an outlet, which will enable you to switch the installed hood on and off, or to an
outlet with a multi-pole switch with at least 3-mm gap between contacts. The manufacturer bears no responsibility in cases, where not all
binding standards for installation safety and safe operation of electrical equipment were observed.

MAINTENANCE

Before conducting any actions, please ensure, that the power supply cable is disconnected from the outlet or the switch is in OFF position.
Cleaning: External parts should be cleaned using a soft cloth dampened with a liquid, non-corrosive cleaning agent. Do not use any powders
or brushes.
SAFETY PRECAUTIONS
When cleaning, please observe manufacturer's recommendations, especially where residues on cleaned surfaces are concerned, to avoid
potential fire hazard. Burners should always be covered to avoid filter overheating. Do not leave a frying pan unattended: the oil can overheat
and ignite. When using oil, the risk of self-ignition raises. It is absolutely forbidden to cook dishes with open flames under the hood. The air
cannot be directed to the ventilation duct by any means but by electricity, and an appropriate room ventilation system should be in place, in
case any other devices, powered by any different means, are used at the same time that the hood is. If the hood is connected to a ventilation
duct, you should ensure, that the duct is in good condition, even if it has not been used for an extended period of time. Remember to always
observe any local standards and regulations of authorities in power concerning extraction of air, in case the hood operates connected to the
ventilation duct.
THE MANUFACTURER BEARS NO RESPONSIBILITY, IF NOT ALL OF THE RECOMMENDATIONS LISTED ABOVE,
CONCERNING HOOD INSTALLATION, MAIINTENANCE AND PROPER USAGE, ARE OBSERVED.
Control
The " " and " " buttons control the fan speed from 1 to 4.
" " button
" " button
-
"
" button (Timer) – sets up the fan switch-off time
Lighting button
– switches the hood light on and off, independently from engine operation. Every time the button is pressed, the
light switches on or off,
Timer: to enable programming automatic switch off at any given time between 10 and 90 minutes, with 10-minute increments.
- To enable programming function, turn the engine on using the " " button to the level you want, and then press the button to
program the switch-off time. The display will show a blinking 0, which means, that the time programming mode was entered.
- Select the automatic switch-off time using the " " button, keeping in mind, that the number on the display, multiplied by the
10-minut interval, means the time of automatic switch-off (e.g. 1=10 min, 2=20 min, 3=30min, etc.)
- With the auto switch-off timer set, confirm the setting using the timer button, the display will stop blinking and will show the
previously selected speed, and the blinking dot next to the speed will show the switch-off time. You can cancel the automatic
switch-off function by pressing the timer button again while the time is counted down.
Caution: Timer programming should be completed within 20 sesonds, otherwise no action will be taken, and the hood will resume
operation in normal mode.
Should the control panel get locked, disconnect the hood from the power supply outlet and reconnect it after 5 minutes. After this time, the
control panel will resume normal operation.
- pressing this button increases the fan speed
- pressing this button decreases the fan speed
14

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Idkg xuk

Inhaltsverzeichnis