Installation
Assembly and installation of the device must be carried out by a specialist familiar with
the hazards and the relevant regulations. Maintenance, operation and commissioning
of this device must only be carried out by qualified persons.
When choosing a location for your device, make sure to avoid impact, vibration, dust,
hot and cold temperatures and dampness. Furthermore, no powerful transformers or
motors must be used close to the device.
The effect light must only be installed in locations with an ambient temperature of no
more than 45°C. The maximum casing temperature is 60°C.
The device must be mounted out of normal reach.
Illuminated objects must be at least 0.5m away from the device's light emission source.
Easily flammable materials such as decorative fabrics must have a distance of at least
1m to the device. Otherwise, such objects may catch fire!
When mounting the product, make sure that the power cord is neither jammed nor
damaged by sharp edges.
During installation or service work, the area below the place of installation must be
cordoned off.
The area or equipment of installation must be designed in such a way that it can support
the tenfold rated load for at least one hour without being deformed permanently.
It is also essential that the device is secured by means of a second safety restraint that
is independent of the actual mounting supports when installing it in an elevated position.
No part of the installation must fall down if the main support system fails.
Observe all relevant regulations when mounting the device.
Acceptance of installation (for industrial use):
Before first use and after any significant modifications, the installation (including the electrical
connections) must be inspected by an official expert.
A yearly inspection by an expert is required.
At least every 4 years, an acceptance test must be carried out by an expert.
21