Technical Data - LumaSense Technologies PI 6000 Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

1.6
Disposal / decommissioning
Inoperable IMPAC controllers and pyrometers have to be disposed corresponding to the local regulations of
electro or electronic material.
2

Technical data

Measured data display:
Program no. display:
Controlled variable display:
Controller cycle time:
Proportional element Xp:
Integration time Ki:
Differential time Kd:
Controlled variable limiting:
Duration of a program step
(segment):
Number of programs:
Number of steps:
AutoTune mode
Power supply:
Power consumption:
Analogue input 1:
(measurement pyrometer)
Analogue input 2:
(optional alarm pyrometer)
Analogue output:
(electrically
isolated from the power supply)
Digital interface to the py-
rometer:
Digital interface to the PC:
(electrically isolated from the power
supply)
Control input:
Control outputs:
Operating temperature:
Storage temperature:
Weight:
Ingress protection:
Protection class:
Display resolution:
4-digit 7-segment LED display, 13 mm, red
Display of the unit of measure °C or °F, 7 mm, red
Single digit 7-segment LED display, 13 mm, red
10-section vertical LED bar display, approx. 4.5 mm wide, red
250 µs
0.0...1000.0%
0 to 10 minutes in 10 ms steps
0 to 10 minutes in 10 ms steps
0.0...100.0%
1
Up to 27 minutes in
/
10
up to 45.5 hours in 10 s steps, "CONT" for continuous operation
Maximum 9
Maximum 20 per control program
For determining Xp and Ki (Kd = 0) for a control temperature
18... 30 V DC, ripple < 50 mV
Approx. 2.5 W (controller without external load)
0/4... 20 mA, input resistance approx. 120 Ω, for transferring the measured
values from the pyrometer to the PI 6000
0/4... 20 mA, input resistance approx. 120 Ω, for the connection of an addi-
tional pyrometer for shut-down in case of overtemperature (safety shut-
down). It is only possible to use alarm pyrometers with positive measuring
range limits.
0/4... 20 mA output, load max. 500 Ω, continuous controlled variable
0...100%
Can be changed between RS232 or RS485 half duplex, for communication
with the measurement pyrometer. The transmission speed is automatically
adjusted to the same speed as is set on the PC interface.
RS232, transmission speed 9600... 38400 Bd
for connection to a PC or a higher level controller (PLC)
Contact (normally open) for starting and stopping the selected control pro-
gram, power supply positive or negative can be used as the reference
4 semiconductor relays, maximum load 50 VDC or 36 VAC 0.2 A
- Signal when a control program is running
- Signal when the generator is to provide power
- Signal when the alarm pyrometer (option) has triggered a safety shut-down
- Pulse of selectable length when the control program has been completed
0 ... 50°C at the housing
-20 ... 70°C
Approx. 250 g
Front IP40, terminals IP20 (in accordance with DIN 40 050)
Protection class III (in accordance with EN61140)
1°C or 1°F