Herunterladen Diese Seite drucken

Uninstallation - Danfoss CF-RF Instruktion

Raumthermostat mit infrarot-bodensensor
Vorschau ausblenden Andere Handbücher für CF-RF:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 14
Instruction CF-RF Room Thermostat with Infrared Floor Sensor
strong artificial light (e.g. halogen spotlight),
draught, other heat-emitting equipment (e.g. TVs)
etc. is avoided.
! Please note that no furniture, rugs etc. should be
permanently placed within the area of the InfraRed
Floor Sensor as shown in fig. 3.
Mounting - fig. 2
. Mount the back plate
and wall plugs
back plate
2. Slide thermostat into place on the back plate
3. If desired lock the thermostat to the back plate
with Allen key

6. Uninstallation

Activate Uninstall mode on Master Controller
- fig. 1
• Use the Menu selection button
the Uninstall menu. Uninstall LED
• Activate Uninstall mode by pressing OK
Uninstall LED
Deselect output on Master Controller
• Select output to be removed by output selec-
tion button
• Remove flashing output
VI.UH.R2.1C
0
with the two screws
via the screw holes
(turn 90°)
goes ON
with OK
Produced by Danfoss Floor Heating Hydronics 03.2007