Do not lubricate the motor bearings or internal parts!
Saw arm bearings
Lubricate the saw arm bearings every 50 hours. Pro-
ceed as follows (Fig. 15).
• Turn the saw to the side
• Apply a generous amount of SAE 20 oil to the shaft
end and bronze bearings.
• Let the lubricant oil work in overnight.
• Repeat the procedure the next day on the other
side of the saw.
There are no parts inside the equipment which re-
quire additional maintenance.
Special accessories
Pin saw blade-universal
135 x 2,0 x 0,25 Z 10
blade mm 1 set = 6 pieces, Article No. 8800 0011
Pin saw blade- wood/plastic mm
135 x 2,0 x 0,25 Z 7
1 set = 6 pieces,
Pin saw blade-wood mm
135 x 3,0 x 0,5 Z 4
1 set = 6 pieces,
Service information
Please note that the following parts of this product
are subject to normal or natural wear and that the fol-
lowing parts are therefore also required for use as
consumables.
Wear parts*: Carbon brush, saw blade, table liners,
Vbelts
* Not necessarily included in the scope of delivery!

10. Storage

Store the device and its accessories in a dark, dry
and frost-proof place that is inaccessible to children.
The optimum storage temperature is between 5 and
30˚C. Store the electrical tool in its original packag-
ing.

11. Electrical connection

Check the electrical connection cables for damage
regularly. Make sure that the connection cable does
not hang on the power network during the inspection.
The installed electric motor is completely wired ready
for operation.
Electrical connection cables must comply with the
applicable VDE and DIN provisions. Only use con-
nection cables with the marking „H07RN".
The printing of the type designation on the connec-
tion cable is mandatory.
The customer's mains connection as well as the
extension cable used must also comply with these
regulations.
 www.scheppach.com  service@scheppach.com  +(49)-08223-4002-99  +(49)-08223-4002-58
Article No. 8800 0012
Article No. 8800 0013
Important remark:
The motor is automatically switched off in the event
of an overload. The motor can be switched on again
after a cooling down period that can vary.
Defective electrical connection cables
Electrical connection cables often suffer insulation
damage.
Possible causes are:
• Pinch points when connection cables are run
through window or door gaps.
• Kinks resulting from incorrect attachment or laying
of the connection cable.
• Cuts resulting from running over the connecting
cable.
• Insulation damage resulting from forcefully pulling
out of the wall socket.
• Cracks through aging of insulation.
Such defective electrical connection cables must not
be used as the insulation damage makes them ex-
tremely hazardous.
With a single-phase a.c. motor, we recommend a C
16A or K 16A fuse for machines with a high start-up
current (from 3000 Watt)!
Single-phase motor
• The mains voltage must be 220 - 240 V~
• Extension cables up to 25 m long must have a
cross-section of 1.5 mm
.
2
Only a qualified electrician is permitted to connect
the machine and complete repairs on its electrical
equipment.
In the event of enquiries please specify the following
data:
• Motor manufacturer
• Type of current of the motor
• Data recorded on the machine's rating plate
• Data recorded on the switch's rating plate

12. Disposal and recycling

The equipment is supplied in packaging to prevent
it from being damaged in transit. The raw materials
in this packaging can be reused or recycled. Never
place batteries in your household refuse, in fire or in
water. Batteries should be collected, recycled or dis-
posed of by environment-friendly means. The equip-
ment and its accessories are made of various types
of material, such as metal and plastic. Defective
components must be disposed of as special waste.
Ask your dealer or your local council.