Page GB-20
Start-up
Space requirement (when the door is open and when the door is closed)
– To prevent the formation of a flammable
gas-air mixture in the event of a leakage
in the refrigeration circuit, the installation
space must have a minimum size of 1 m
per 8 g of refrigerant in compliance with
the EN 378 standard. The amount of re-
frigerant contained in your appliance can
be found on the data sheet page GB-27. The
minimum size of the area in which your ap-
pliance is set up is as follows:
Model A1
Model A2
5.75 m ³
5.75 m ³
– Suitable locations are dry, well-ventilated
areas that are cool if possible.
– Unsuitable locations are ones with direct
sunlight or which are directly next to an
oven, hob or radiator.
– If underfloor heating is installed at the set-
up location, place the cooling appliance on
an insulation plate made from solid mate-
rial.
3
Model A3
7.2 m ³
840