Connection with the mains

Connect the device to the mains with the power plug. The occupation of the connection cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green Earth
Attention! The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.

OPERATION

Connect the remote control with the Remote Control-socket.Switch the device on via the power switch.
CAUTION: The escape nozzle will heat up during operation. Therefore do not touch the nozzle until it
has cooled down completely.

CLEANING AND MAINTENANCE

We recommend a frequent cleaning of the device. Please use a soft lint-free and moistened cloth. Never use
alcohol or solvents!
Clean the escape nozzle frequently from smoke fluid residues. Clean out debris with vinegar and a pipe
cleaner, making sure that the hole is free of clogs.

Cleaning the heating element

The heating element should regularly be cleaned every 30 operational hours in order to avoid clogging. Use
smoke-machine cleaner available at your dealer.
Procedure:
Fill cleaner into empty tank. Run the machine several times in a well-ventilated room only. The number of
repititions depends on the pollution level of the vaporizing elements. After use clean all remaining cleaner
and rinse the tank thoroughly with distilled water.
International
L
N
After a certain warm-up time, the device is ready to operate. Then
the stand-by lamp of the remote control lights up. By operating the
smoke switch on the remote control the smoke emission starts. It
may happen that the stand-by lamp turns off and the smoke
emission stops. In this case the device is heating up again and will
be ready to operate in approx. 1-2 min. This process guarantees an
appropriate vaporization temperature and the best smoke emission
possible. The temperature is regulated by a high quality thermostat.
DANGER TO LIFE!
Disconnect from mains before starting maintenance operation!