6. Transport, packaging ... / 7. Commissioning, operation
6.3 Storage
Permissible conditions at the place of storage:
Storage temperature: -20 ... +70 °C

7. Commissioning, operation

Mechanical connection
In accordance with the general technical regulations for pressure gauges
(e.g. EN 837-2 "Selection and installation recommendations for pressure
gauges").
If the pressure gauge is mounted lower than the pressure tapping, the
capillary must be fushed thoroughly before connection in order to clear out
any foreign matter.
When screwing gauges in, the force required for this must not be applied
through the case, but rather through the spanner fats (using a suitable tool)
provided for this purpose on the square shaft of standard connections.
Installation with
spanner
Correct sealing of pressure gauge connections with parallel threads
be made using suitable sealing rings, sealing washers or WIKA profle seals.
The sealing of tapered threads (e.g. NPT threads) is made by providing the
thread
, with additional sealing material such as, for example, PTFE tape
(EN 837-2).
The torque depends on the seal used. Connecting the gauge using a clamp
socket or a union nut is recommended, so that it is easier to orientate the
gauge correctly.
WIKA operating instructions models PGS10, PGS11 and PGS21
Wrench surface
Sealing face
Sealing in the
thread