Troubleshooting

12.1 E1 - Damage to the safety temperature limiter

The sensor contained in the scope of supply has no safety temperature limiter. Verify the correct fit of the wire
bridge installed at the factory.

12.2 E2 - Cabin sensor - interruption

Check the cable for damage and the terminals for correct fit.
12.3 E3 - Cabin sensor – short circuiting
Verify the cable of the cabin sensor for damage.

12.4 E4 - Film sensor - interruption

If you are not using films or hotplates, the dummy sensor installed at the factory (Fig. 5; terminals b -b) must
remain in position.
If you are using a film sensor, check the cable for damage and the terminals for correct fit.
12.5 E5 - Film sensors – short circuiting
If you are using a film sensor, check the cable for damage and the terminals for correct fit.

12.6 E6 - Film excess temperature error

If you are not using a film sensor, check the dummy sensor installed at the factory for correct fit.
If you are using a film sensor, check the cables of the film sensor for damage and the terminals for correct fit.
If the errors are not rectified by means of the aforementioned measures,
contact your dealer. Do not continue to use the device under any circumstances.