15 Technische Daten

Allgemeine Angaben gelten für den Temperaturbereich 5 °C bis 40 °C. Genauigkeitsangaben gelten
für den Temperaturbereich 18 °C bis 28 °C nach 15 Minuten Aufwärmzeit ohne Last und Kalibrierung
bei 23 °C. Typische Spezifikationen sind durch das Design bestimmt und nicht garantiert.
OUTPUT SPECIFICATIONS (Each Output)
Voltage/Current
Ranges:
Output Power:
Voltage Setting:
Current Setting:
Operating Mode:
Output Switch:
Multi-On/Multi-Off
Action:
Output Terminals:
Ripple & Noise
(20MHz bandwidth):
Load Regulation:
Line Regulation:
Transient Response:
Temp. Coefficient:
Voltage Programming
Speed MX100TP only:
(Typical figures)
35V 3A
16V 6A
70V 3A
35V 6A
Telemeter Electronic GmbH | Joseph-Gaensler-Str. 10 | Phone +49 906 70693-0 | Fax +49 906 70693-50 | www.telemeter.info
O/P1: Switchable 0V to 35V/0.1mA to 3A or 0V to16V/0.1mA to 6A
O/P2: 0V to 35V/1mA to 3A, 0V to 16V/1mA to 6A
or 0V to 35V/1mA to 6A with O/P3 disabled.
O/P3: 0V to 35V/1mA to 3A, 0V to 70V/1mA to 1.5A
or 0V to 70V/1mA to 3A with O/P2 disabled
Up to 315W total output power
Resolution: 1mV O/P1; 10mV O/P2 and O/P3
Accuracy: O/P1: 0.05% of setting ± 3mV,
O/P2 and O/P3: 0.1% of setting ± 10mV
Resolution: 0.1mA O/P1; 1mA O/P2 and O/P3
Accuracy: ± (0·3% + 3mA) to 3A, ± (0·5% + 3mA) to 6A
Constant voltage or constant current with automatic cross-over.
CV or CC mode indication in display.
Independent electronic switching with ON indication. In addition, Multi-On
and Multi-Off keys permit the outputs to be switched on/off synchronously.
Individually settable delay between pressing of the Multi-On or Multi-Off key
and the turning on or off of the respective output. Delays settable between
10ms and 20 seconds. Separate delays for On and Off can be set.
Outputs can also be omitted from Multi-On or Multi-Off control.
Universal 4mm safety binding posts on 19mm (0·75") spacing for Output;
screwless terminals for Sense.
MX100TP also has duplicate power and sense terminals at rear.
Outputs 1 and 2 loaded at 16V/6A, Output 3 loaded at 35V/3A, CV mode:
All Outputs typically <0.5mVrms, <5mV pk-pk; 1mVrms max.
O/P 3 on 70V/3A range: typically <1mVrms, <10mV pk-pk; 1.5mVrms max.
For any load change, measured at the terminals, using remote sense:
Constant voltage: <0.01% ± 5mV
Constant current: < 0.01% ±0.5mA
Change in output for a 10% line change:
Constant voltage: <0.01% ± 5mV
Constant current: < 0.01% ± 250uA
<100us to within 50mV of set level for a 5% to 95% load change.
Typically <100ppm/°C
Maximum time required for output to settle within 1% of its total excursion
(for resistive load). Excludes command processing time.
90% Load
Up
10ms
Up
10ms
Up
25ms
Up
10ms
Seite 44
No Load
10ms
Down
10ms
Down
12ms
Down
10ms
Down
90% Load
No Load
35ms
550ms
10ms
350ms
60ms
600ms
20ms
550ms
45