Evaluation of measuring results;
Selection of electrical installation material for
safeguarding shut-off conditions;
IP protection types;
Installation of electrical installation material;
Type of supply network (TN system, IT sys-
tem, TT system) and the resulting connecting
conditions (classical zero balancing, protective
earthing, required additional measures etc.).
Installation may only take place in normal commercial
switch boxes (device boxes) in accordance with DIN
49073-1.
When installing many flush-mount actuators in
installation boxes that are one above the other
or adjacent to one another (connected or not),
the total switching current of 16 A is not to be
exceeded!
The installation of the described actuators is shown in
the following connection diagrams.
Connect the actuators to L and N for the supply.
Channels for buttons exist at the button inputs.
Run the channel circuit to the consumer.
38
No operational elements are actually located on the
devices. For teaching directly without HomeMatic
Centre, you must (even if only temporarily) connect
buttons!
The control inputs are connected to mains power.
Use only mains power capable buttons and wiring!
Only connect buttons to the inputs, no switches!
These would cause faulty functionality of the device
(teach mode)!