Herunterladen Inhalt Inhalt Diese Seite drucken

Specifications - GREISINGER GMH 5155 Betriebsanleitung

Zweifach-druck-handmessgerät wasserdicht, mit datenlogger
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

H82.0.03.6C-08

18 Specifications

Display range
Number of channels
Suitable probes
Available ranges/resolutions
Connections
sensor
output /
ext. supply
Display units
User unit
Measuring frequency
Accuracy
Working conditions
Storage conditions
Display
Correction function
Leakage test function
Air velocity / volume flow
Real-time clock
Data logger
cyclic
manual
Alarm
channels
types
Additional functions
Averaging
Housing
protection class IP65 and IP67
dimensions
L*W*H [mm]
Power supply
current
consumption
Battery-change indicator
Auto-off-function
EMC
Operating Manual GMH 5155
_____________________________________________________
maximal -19999...19999 digit, depends on used sensor
2
GMSD ... - K51 and MSD ... sensors with connection cable MSD-K51
ranging from -1.999 ... 2.500 mbar / 0.001 mbar to 0 ... 1000 bar / 1 bar
two 7-pole bayonet connectors
4-pole connector for serial interface and supply (USB Adapter USB 5100)
analog output 0-1V, adjustable
depends on meas. range selection (depends on connected sensor):
mbar, bar, Pa, kPa, MPa, mmHg, inHg, PSI, mH
freely adjustable
4 / s or 1000 / s
± 0.1 % FS ± 1 digit
-25 ... 50 °C; 0 ... 95 %RH (non condensing)
-25 ... 70 °C
4 ½ digit 7-segment display, illuminated (white)
offset / slope (via menu),
if offset/slope value not equal zero: "corr" is displayed
Pressure change rate display, configurable time base
measuring with pitot tube
integrated clock with date and year
8000 data sets
1000 data sets (with measuring point input,
40 adjustable measuring point text numbers)
3 (sensor 1, sensor 2, difference) with individual alarm boundaries
buzzer/visual/interface
min- / max- / hold- function
adjustable, 1 ... 120 seconds
160 * 86 * 37 incl. protective covering,
approx. 250 g incl. batteries and protective covering
2*AAA-batteries (included in delivery)
2.0 mA (at Out = Off, equivalent to 500 h),
illumination ~10mA (turns off automatically)
automatically if battery exhausted "bAt", warning "bAt" flashing
Device will be automatically switched off if no key is pressed/no interface
communication takes place for the time of the power-off delay.
The power-off delay can be set to values between 1and 120 min.; it can be
completely deactivated.
The device corresponds to the essential protection ratings established in the
Regulations of the Council for the Approximation of Legislation for the member
countries regarding electromagnetic compatibility (2004/108/EG)
Additional fault: <1%
_____________________________________________________________________________
O
2
page 21 of 22

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis