Installation instructions, only for experts
5.7. Installing bench sensor F2 (optional)
1. Guide the wires for the bench sensor through the cable bushing
low-voltage connection area
2. Connect the wires for the bench sensor to the terminals labelled "sw-br" in
terminal strip
5.8. Installing humidity temperature sensor FTS2 (optional)
1. Guide the wires for the sensor through the cable bushing
voltage connection area
2. Connect the wires for the temperature sensor lines to the terminals labelled
"sw-br" in terminal strip
a. Connect the black wire to terminal "sw".
b. Connect the brown wire to terminal "br".
3. Connect the wires for the humidity sensor to the terminals labelled "or-rt-gn"
in terminal strip
c. Connect the orange wire to terminal "or".
d. Connect the red wire to terminal "rt".
e. Connect the green wire to terminal "gn".
5.9. Finishing the installation
● Screw two cross-head screws into the lower fastening holes
● Ensure that the sauna control unit is fitted securely.
● Place the control panel onto the housing lower part. To do so, insert tabs into
the two lateral holders and press onto the housing lower part until the stop
position.
● Place the housing cover onto the housing lower part, swivel downward and
press until it clicks audibly.
WORLD OF WELLNESS
4
.
3
.
4
.
3
.
2
.
p. 16/44
into the
8
into the low-
8
(Fig. 2).
5