Installation instructions, for professionals only

5.6. Connecting heater sensor F1

1. Guide the wires for the heater sensor through the cable bushing 9 into the
low-voltage connection area 5.
2. Connect the red wires for the heater sensor to the terminals labelled "r-r"
in terminal strip 4.
3. Connect the white wires for the heater sensor to the terminals labelled "w-w"
in terminal strip 4.

5.7. Installing bench sensor F2 (optional)

1. Guide the wires for the bench sensor through the cable bushing 7 into the
low-voltage connection area 5.
2. Connect the wires for the bench sensor to the terminals labelled "sw-br" in
terminal strip 4.

5.8. Installing humidity temperature sensor FTS2 (optional)

1. Guide the wires for the sensor through the cable bushing 7 into the low-
voltage connection area 5.
2. Connect the wires for the temperature sensor lines to the terminals labelled
"sw-br" in terminal strip 4.
a. Connect the black wire to terminal "sw".
b. Connect the brown wire to terminal "br".
3. Connect the wires for the humidity sensor to the terminals labelled "or-rt-gn"
in terminal strip 4.
c. Connect the orange wire to terminal "or".
d. Connect the red wire to terminal "rt".
e. Connect the green wire to terminal "gn".