2.5 Outside air intake
For this equipment combustion air can also be added from the outside. It
makes installation easier in houses with passive and low energy consumption if
the ventilation in the living quarters is controlled. Connection is possible
through a tube with a diameter of 100 mm. The combustion air supply pipe has
to be equipped with a stop-cock close to the stove. Of course, heating is also
possible with the air of the room – see: Item 2.2 (Germany).
The stoves use room air for combustion, and a sufficient supply of combustion
air is therefore essential. The air pressure in the room of installation must not
be negative. Please observe the relevant technical rules / regulations and any
additional information when operating your appliance in combination with air
conditioning systems (for ex. ventilation systems, exhauster hoods, pneumatic
conveyor systems etc.).
outside air intake
111 50 BOSTON
111 51 CHICAGO
111 53 MANHATTAN
Ø 98 mm