REFRESHING THE OIL
1. Place the generator on a level surface and warm up the engine for several
minutes Then stop the engine.
2. Remove the oil filler cap.
3. Place the oil collect can under the motor, unscrew the oil drain plug and drain
the oil completely.
4. Replace the oil drain plug.
5. Fill with fresh oil up to the maximum level.
6. Replace the oil filler cap.
Caution: be sure no foreign material enters the crankcase.

8. APPLICATION RANGE

AC application
Model
AC output
Rated voltage
Frequency
AC current
Rated output
Max. output
50 Hz
230 V
50 Hz
230 V
50 Hz
1600 - 2200 W
230 V
Unit
V
Hz
A
VA
VA
29
75029
2300 W
1800 W
Power
factor
1
0,7~0,8
0,7~0,95
75029
230 V AC
50
9,1
2000
2400