Cookers with a three-pole power supply cable are
designed to operate with alternated current at the supply
frequency and voltage indicated on the data plate (at the
bottom of the oven dashboard). The earthing conductor
of the cable is the yellow-green conductor.
Connecting the power supply cable to the mains
The appliance must be directly connected to the mains
using an omnipolar circuit-breaker with a minimum contact
opening of 3 mm installed between the appliance and the
mains, suitable for the load indicated and complying with
current directives (the earthing wire must not be interrupted
by the circuit-breaker).
Oven size
width
depth
Height
Powers supply:
- Static oven:
- Lower heating element:
- Upper heating element:
- Grill:
- Ventilated grill:
- Gentle pastry oven:
- Ventilated oven:
Electric oven size:
Voltage end frequency:
Power supply Max:

Electric connection

The power supply cable must be positioned so that it does
not exceed 50°C more than room temperature at any point
of its length.
Before making the connection check that:
l
l
l
NOTE: do not use reducers, adaptors or shunts as they
could cause overheating and burns.

Technical Specifications

This appliance conforms with the following European
Economic Community directives:
cm. 54
cm. 38
-
cm. 33
-
W 2350
-
W 1300
W 1050
W 2000
W 2000
W 1300
ENERGY LABEL
W 2350
Directive 2002/40/EC on the label of electric ovens
Norm EN 50304
L. 68
Energy consumption for Natural convection
heating mode:
Declared energy consumption for Forced convection Class
230 V / 50-60 Hz
heating mode:
2400 W
17
the limiter valve and the home system can support the
appliance load (see data plate);
the power supply system has an efficient earthing
connection which complies with the provisions of
current regulations;
the socket or omnipoar circuit-breaker is easily
accessible once the cooker has been installed.
73/23/EEC of 19/02/73 (Low Voltage) and subsequent
modifications;
89/336/EEC
of
03/05/89
Compatibility) and subsequent modifications;
93/68/EEC of 22/07/93 and subsequent modifications.