Instructions for the Installer

The instructions given below are
designed specifically for a qualified
installer and should aid him or her to
perform all installation, adjustment, and
maintenance operations with absolute
precision and in compliance with all
current legislation and regulations. We
strongly
recommend
operations for the installation of your
cooker be carryed out by Qualified Per-
sonnel in accordance with existing
rules and regulations.

Electrical connection

Prior to making the electrical connection, make sure that:
— the protection fuse and the domestic wiring
system are suitable to carry the total electric load of
the oven (see rating plate);
— your domestic wiring system has an
efficient earth connection in compliance with rules
and laws in force;
— the wall socket or the omnipole switch used
for the electrical connection can easily be reached
after the oven is built in.
This appliance is delivered without an electric supply
cable, therefore, you will have to fit to it a supply cable
with standard plug, suitable for the total electric load
shown on the rating plate. The plug is to be inserted into
a suitable wall socket. If you require a direct connection
to the electric network (mains), it will be necessary to fit
between the appliance and the mains an omnipole
switch, with a minimum gap between contacts of 3 mm,
suitable for the required load and in compliance with
rules in force. The green & yellow ground wire must
not be interrupted by the switch, and should be 2-3 cm
longer than the phase and neutral wires. The supply
cable must in all cases be laid out in such a way as to
ensure that it does not reach at any given point a
temperature 50°C higher than the ambient
temperature.
Suitable power supply cables are the following types,
considering the respective necessary section of cable:
H07 RN-F, H05 RN-F, H05 RR-F, H05 VV-F, H05
V2V2-F (T90), H05 BB-F.
Connecting the terminal board
The appliance incorporates an easily accessible 6-pole
terminal board whose jumpers (bridges) are already
pre-set for operation on 400 V tri-phase with neutral wire
(Fig. 12). In case a different mains voltage is present, the
jumpers on the terminal board must be rearranged as
shown in the diagram (Fig. 13). The ground cable must be
connected to terminal
cable to the terminal board, secure it with a junction clamp.
that
all
Electrical connection with the hob
This oven can be connected to hobs indicated in the
paragraph "Technical data". The socket for
connecting the hob is located at the top of the oven
cabinet. The hobs come complete with connecting
leads for the hot plates/heat areas and ground cable;
these leads feature plug-in connectors. Connection of
the hob to the oven is carried out by plugging-in these
connectors to the corresponding oven socket.
The plug-to-socket connection design is such as to
prevent possible wrong plugging-ins.
The Manufacturer disclaims any liability in case
these accident-preventing rules are not
observed.
Fig. 12
Fig. 13
. After connecting the supply
1 2 3 4 5
230V 3~
Ø 4x2,5mm²
L1
L2
1 2 3 4 5
230V 1~
Ø 3x2,5mm²
L1
1 2 3 4 5
400V 2N~
Ø 4x2,5mm²
L1 L2
1 2 3 4 5
400V 3N~
Ø 5x1,5mm²
L1 L2 L3 N
Electrolux
L3 PE
N
PE
N
PE
PE