Herunterladen Inhalt Inhalt Diese Seite drucken

Usb Port Socket (Accessory); Error Messages - Bonnet EQUAJET Bedienungsanleitung

Kombidämpfer
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

8.4
AUTO CLEANING MENU
Pressing the Cleaning/Tools button or any
inactive zone exits this menu and returns to the
previous screen.
The USB port socket is fitted with silicone protective cover.
Warning !
Always put the protective cover in place (lowered to protect connections) whenever the socket is not in use.
Never "clean" connections with a water hose or a sponge. (If the silicone cover is used and put back in place after use, no
maintenance is necessary).
The guarantee will not apply if these recommendations are not observed.

4.1 ERROR MESSAGES

Message on the screen
i31 : Electronics overheating: Temperature
reduced to 180°C
i33 : Core probe non function or not plugged in
i81 : Water flow problem
i82 : Sticking solenoid
E46 : Electronic communication fault
E53 : Ventilation non function
E61 : Ambient probe short circuit
E62 : Ambient probe non function
E68 : Cavity at +290°C
E72 : Electronics at over + 75°C
E73 : Detergent pump faulty or on permanently
Page 6
Pressing the Cleaning/Tools button gives access to the cleaning menu
Display shows "CLEA" (cleaning) in the timer zone and the intensity in the temperature
zone.
By default the last cycle used is displayed.
Possible selections:
- 3 cleaning intensities
- Rinse function
- Cleaning product priming function
The priming function allows the detergent delivery circuit to be refilled when the
container is changed so that efficiency is maintained
Pressing the "Start button" starts a wash cycle.
3

USB PORT SOCKET (ACCESSORY)

4
ERROR MESSAGES
Consequences
Cooking continues automatically at
a temperature below 180°C
Cooking stops
Reduced functionality or Pause
the cleaning
Reduced functionality
Cooking stops
Cooking stops
Cooking stops
Cooking stops
Cooking stops
Cooking stops
Drain the hydraulic circuit.
Reduced functionality
Intensity
1
2
3
Rin
Pri
What to do?
Clean the lower and rear air intakes. If the problem
persists, call a service technician.
To continue cooking connect a probe or switch to timer
mode.
Check the valve and water pressure.
If this message appears during washing: the cavity must
be rinced thoroughly.
If the problem persists, call a service technician.
Switch off and call a service technician.
Possible to launch safe mode: convection mode at
175°C (see guidance and info about the control screen).
Switch off and call a service technician.
Switch off and call a service technician.
Switch off and call a service technician.
Switch off and call a service technician.
Switch off and call a service technician.
Switch off and call a service technician.
BONNET GRANDE CUISINE
Rue des Frères Lumière - Z.I Mitry Compans
77292 MITRY MORY Cedex
3B-390977NU – 01/17
Time
6/10 lev
20 lev
17 min
26 min
26 min
36 min
36 min
37 min
2 min
2 min
2 min
2 min

Werbung