10. PARAMETER DISPLAY

a) Battery Voltage

The voltage of the battery is indicated in the unloaded condition (and can therefore not be
measured during operation).

b) Charge Condition

To give you a general idea of the state of the rechargeable battery this device displays a
battery symbol („ "). This symbol only serves to estimate how far the charge or discharge
process has progressed. When charging the battery icon fills from the bottom to the top
while it empties from top down when discharging.
During automatic multi-step charging of NiZn batteries, the bar graph display (battery icon)
indicates the progress of the respective charge condition.
Conclusions regarding the expected time remaining until the end of the programme are not
possible from it.

c) Charge/Discharge Current

When charging and discharging the current flowing into the battery „I" is displayed. If no
current is flowing (e.g. in the mode „RDY" („READY") or „ERR" („ERROR"), the display
shows „I = 0.000A".

d) Time Measurement

The display shows the time in hours and minutes („HH:MM") over which the battery was
charged and discharged. The time required for maintenance charge (operating mode
„TRI" = „TRICKLE") is not considered.

e) Fed in and Removed Capacity

The capacity (C) charged into the battery, as well as the discharged capacity (D) is stated
in milliampere hours (mAh).
In programmes with several charge and discharge cycles, only the current values are
displayed. Data of the previous cycle are deleted. No calculation, display or addition of the
capacity of a maintenance charge („TRICKLE") are performed.