– not be exposed to direct sunlight;
– not be installed next to radiators, cookers or other sources of heat;
– only be installed at a location whose ambient temperature corresponds to
the climate classification, for which the appliance is designed.
The climate classification can be found on the serial plate, which is located
at the left on the inside of the appliance.
The following table shows which ambient temperature is correct for each
climate classification: each climate classification:
Climate classification
SN
N
ST
T
If installation next to a source of heat is unavoidable, the following mini-
mum clearances must be maintained at the sides of the appliance:
– for electric cookers 3 cm;
– for oil and coal fired ranges 30 cm.
If these clearances cannot be maintained a heat insulating pad is required
between the cooker and the refrigeration appliance.
Your appliance needs air
For safety reasons, minimum
ventilationmust be as shown Fig.
Attention: keep ventilation ope-
nings clear of obstruction;
for an ambient temperature of
+10 bis +32 °C
+16 bis +32 °C
+18 bis +38 °C
+18 bis +43 °C
min.
50 mm
200 cm
D567
2
min.
200 cm
2