Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

• Press [ENTER], the display shows "C-01".
• Select "CNIN" by pressing [UP] or [DN].
• Press [ENTER], the display shows "OFF".
• Press [UP], the display shows "ON".
• Press [ENTER], the display shows "SC02". You successfully downloaded the first scene.
• Adjust the Step-time as described above.
• Call up the second scene in your controller now.
• Repeat steps 5-11 until all desired scenes are downloaded.
• Press [MODE/ESC] to exit. The number of steps can be defined under "STEP" and the scenes can be
called up under "RUN"

Error Messages

When you turn on the fixture, it will make a reset first. The display may show "XXEr" while there are
problems with one or more channels. "XX" stands for the channels equipped with a testing sensor.
For example, when the display shows "04Er", it means there is some error in channel 4. If there are
some errors on channel 4, channel 5, channel 6 at the same time, you may see the error message
"04Er", "05Er","06Er" flash repeatly for 5 times, and then the fixture will generate a reset signal, all
the stepper motors will reset. If the error messages maintain after performing reset more than 3
times, it will detect whether the fixture has more than 3 errors. If the fixture has more than 3 errors
(including 3 errors), all the channels can not work properly; but if the fixture has less than 3 errors,
only the channels which have errors can not work properly, others can work as usual.
01Er:
Horizontal movement (PAN) error. This message will appear if the magnetic-indexing circuit malfunctions
(sensor failed or magnet missing) or the stepping-motor is defective (or its drive circuit on the main PCB)
after the reset. The PAN-position is not located in the default position after the reset.
02Er:
Horizontal movement (TILT) error. This message will appear if the magnetic-indexing circuit malfunctions
(sensor failed or magnet missing) or the stepping-motor is defective (or its drive circuit on the main PCB)
after the reset. The TILT-position is not located in the default position after the reset.
04Er:
Color-wheel error. This message will appear after the reset of the fixture if the magnetic-indexing circuit
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its drive circuit on the
main PCB). The color-wheel is not located in the default position after the reset.
05Er:
Rotating gobo-wheel error. This message will appear after the reset of the fixture if the magnetic-indexing
circuit malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its drive circuit on
the main PCB). The rotating gobo-wheel is not located in the default position after the reset.
06Er:
Rotating gobo indexing error. This message will appear after the reset of the fixture and if the magnetic-
indexing circuit malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its driver
circuit on the main PCB). The rotating gobo is not located in the default position after the reset.
07Er:
Prism error. This message will appear after the reset of the fixture and if the magnetic-indexing circuit
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its driver circuit on the
main PCB). The prism is not located in the default position after the reset.
09Er:
Focus error. This message will appear after the reset of the fixture and if the magnetic-indexing circuit
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its driver circuit on the
main PCB). The focus is not located in the default position after the reset.
46/48
00056440.DOC, Version 1.0

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis