For Your Safety
Strictly follow the Instructions for Use
Any use of the oxygen self-rescuer requires full understanding and
strict observation of these instructions.
The oxygen self-rescuer is only to be used for purposes specified
here.
Maintenance
The oxygen self-rescuer must be inspected and serviced regularly by
trained service personnel.
Repair and general overhaul of the oxygen self-rescuer may only be
carried out by trained service personnel.
We recommend that a service contract be obtained with Dräger and
that all repairs also be carried out by them.
Only authentic Dräger spare parts may be used for maintenance.
Accessories
Only use accessories mentioned in the order list.
Disposal
Used or opened units have to be disposed professionally, since the
reaction between the air humidity and the used chemical can
generate an aggressive base.
Description
Oxy K 30 HW/HS/HS KD is an oxygen self-rescuer, independent of
the ambient air, with a closed to-and-fro breathing system which uses
chemically-bound oxygen and a fire escape hood.
Oxy K 30 HW/HS/HS KD has a nominal duration of 30 minutes (at
the breathing rate of 35 L/min according to DIN 58 639). The
operating period can be significantly extended depending on the
users breathing rate.
The Oxy K-Series of oxygen self rescue devices conform to
DIN 58 639 and meet the requirements of EC Council Directive PPE
(89/686/EC).
Intended Use
Oxy K 30 HW/HS/HS KD is intended for emergency escape from
areas filled with smoke or toxic gases or lacking oxygen.
Restriction:
Oxy K 30 HW/HS/HS KD is only suitable for use in the
temperature classes T1, T2, T3 and T4.
CAUTION:
Due to the possible presence of oxygen in the hood, the user
must avoid direct contact to flames or sparks when carrying
the Oxy K 30 HW/HS/HS KD. The presence of oxygen in the
hood increases fire hazards, which can result in serious
injuries or even death.
If the emergency exit is completely blocked by flames and
sparks, direct contact can to a large extent be avoided by
covering the hood with ones own body.
Carrying Method
Oxy K 30 HS/HS KD
Everyday carried on the shoulder.
Other methods are possible, such as
— transport in a vehicle
— on the chest with additional chest strap
— in an emergency on the chest.
10
Before Placing the Oxygen Self-Rescuer into
Service
Before first use, the entrepreneur/user must ensure the following (see
European Directive 89/656/EEC):
— the Personal Protective Equipment must fit perfectly,
— the Personal Protection Equipment must be compatible with other
types of protective equipment worn at the same time (e.g. protec-
tion jacket),
— the Personal Protective Equipment must be suitable for existing
workplace conditions,
— the Personal Protective Equipment must take account of ergono-
mic requirements and the worker's state of health.
Oxy K 30 HS/HS KD
The Oxy K 30 HS/HS KD has to be weighed upon being
delivered.
When weighing the oxygen self-rescuer, detach the harness.
The measured weight has to be compared with the weight on the
metal plate.
CAUTION:
If the weight is more than 6 grams off the listed weight, the
oxygen self-rescuer has to be discarded.
Before placing the oxygen self-
rescuer into service, the customer
has to mark the oxygen self-rescuer
with the dates of the inspection
intervals on the metal plate. The
metal plate is on the backside of the
oxygen self-rescuer.
— The use of letter punches is not
allowed. Dräger recommends
engraving or etching.
— There are six open fields on the metal plate.
st
1
field –date of delivery– fill in month and year
(e.g. 07/03)
nd
st
2
field –1
Inspection– fill in date of delivery plus three years
(e.g. 07/06)
rd
nd
3
field –2
Inspection– fill in date of delivery plus five years
(e.g. 07/08)
th
rd
4
field –3
Inspection– fill in date of delivery plus seven years
(e.g. 07/10)
th
th
5
field –4
Inspection– fill in date of delivery plus nine years
(e.g. 07/12)
th
6
field –End of Lifetime– fill in end of lifetime of the oxygen self-
rescuer. The end of lifetime depends on use and storage (see
"Service Life Record" on page 15)
Furthermore you will find on the metal plate the following dates filled
in by the manufacturer:
— date of manufacturing
— serial number
— part number
— weight
— CE Marking
— Product Standard
— Designation
st
Date of
Date of deli v ery
1
Inspection
manu fact.
Serial Numbe r
nd
2
Inspection
Fill ou t
Part Numbe r
by
customer
rd
3
Inspection
W eigh t
th
End of Li fetime
4
Inspection
CE 0158
DIN 58639