Fill with water to the fill point such that
water starts to run out of the filling
screw (11) hole.
Retighten the filling screw (11).

Operational start-up

Check that the electrical connec-
tion is 230V ~50Hz
Check the proper status of the
electrical plug socket and make
sure that the plug socket is suf-
ficiently fused (at least 10 A). In-
sert the pump plug into the plug
socket and the pump is ready for
operation.
Make sure that moisture or water
never come in contact with the
mains connection.
There is a risk of electrocution.

Starting the unit

Connect the power cable of the auto-
A
matic switch (
ply.
When you connect the appliance to
the mains, all lamps will first of all
light up.
Set the On/Off switch (
the unit.
The "Power On" indicator (
will light up to indicate that the unit is
ready to operate.
The "Pump On" indicator (
you that the pump is working.
In the case of water withdrawal, the
automatic switch is activated automati-
cally and switches on the pump in the
event of a pressure drop in the line. If
the water withdrawal is stopped then
the line pressure increases and the au-
tomatic switch automatically switches
off the pump.
8) to the power sup-
A
7) to turn on
A
19)
A
18) tells
The "Alarm" indicator (
when the appliance turns itself off auto-
matically.

Restarting the appliance

After the equipment is switched off auto-
matically and the "Alarm" display (16)
illuminated, press the restart switch (17).
If restarting the appliance fails several
times, fill up the pump with new water.
Maintenance
Instructions
Clean and maintain your equipment regu-
larly. This will guarantee its performance
and long durability.
Ask our service centre to carry out
any work that is not described in
these instructions. Use only original
parts.
Pull out the power plug before every
maintenance operation. There is a risk
of electrocution or of injury from mov-
ing parts.

General cleaning instructions

A reduction in pump feed output may be
indicative of a blockage. In case the unit
clogs up, remove the suction and pressure
hoses. Dismantle the automatic switch (20)
and flush water through the threaded hole
on the pump in order to remove the foreign
body.
Any measures above and beyond these,
particularly opening the equipment, are
to be carried out by an electrician. In the
case of repairs, always contact our service
centre.