Installation Guide

Connection via the user module UCON-IP-eco

 If necessary, mount the user module in a 19" rack.
Important: Ensure that all interfaces of the user module UCON-IP-eco can be
easily accessed and no heat accumulates.
The operating temperature must not exceed 40 °C.
 Insert one end of the category 5 (or better) twisted pair cable into the
Transmission port of the user module.
 Connect the other end of the twisted pair cable to any of the 16 Console ports of
the matrix switch CATCenter NEO.
 Connect the monitor to the Monitor interface of the user module.
 Connect the keyboard to the PS/2 Keyb. interface of the user module.
 Connect the mouse to the PS/2 Mouse interface of the user module.