Stop!
No device protection in the event of too high mains voltages
The mains input is not fused internally.
Possible consequences:
ƒ
Protective measures:
ƒ
ƒ
EMC−compliant wiring
)
Note!
ƒ
ƒ
ƒ
Integrated safety engineering
)
Note!
ƒ
ƒ
EDKLCFH1134−EPM DE/EN 1.0
Destruction of the device if the mains voltage is too high.
Observe the max. permissible mains voltage.
Fuse the device correctly on the supply side against mains fluctuations and
voltage peaks.
Use a copper braid cable to connect the PE bolt with the mounting surface.
Separate control and data cables from motor cables.
Connect control and data cable shields at both ends.
Please keep the plastic covers on the connectors for the control connections
and interfaces!
Cover unused connections during transport, storage and operation with the
plastic covers to preserve the certified safety engineering features.
l
Electrical installation
Important notes
4