Technical Data
Max. torque:
Operating pressure:
Speed:
Weight:
Noise and vibration
Noise ratings were determined according to
EN 15744. Vibration ratings were determined
according to ISO 28927-2.
Vibration
(per EN 28927-2):
Uncertainty K:
Noise level L
:
pA
Uncertainty K
:
pA
Sound power level L
WA
Uncertainty K
:
WA
L
= 105.3 dB(A)
pC, peak
Uncertainty K = 3 dB
Scope of delivery
1 Air ratchet set
1 Plug nipple with gasket
7 Socket key (10, 11, 13, 14, 15, 17, 19 mm)
1 Extension
3 Bits (PH 2.3, SL 5.5)
1 U-joint
1 Bit holder
1 Oil reservoir
1 Carrying case
1 Instructions for use
General safety rules
Note: When used in the following text, the terms
„compressed air unit" or „device" refer to the com-
pressed air unit specified in these instructions for use.
Basic safety measures must be
followed when using compressed air units to eliminate
the risk of fire, electric shock and personal injury.
Be sure to read and follow the notices within these
43095_par_Druckluft-Ratschenschrauber PDRS_content_SI_CZ.indd 7
61 Nm
6.3 bar
150 rpm
1120 g
2.63 m / s
2
1.5 m / s
2
91.9 dB(A)
3 dB
: 102.9 dB(A)
3 dB
Introduction / General safety rules
operating instructions prior to using the equipment
and store them in a safe location.
The manufacturer assumes no liability for damages
or personal injury resulting from failure to follow these
operating instructions.
Persons (including children) who lack the knowl-
edge or experience to use the tool or whose
physical, sensory or intellectual capacities are
limited must never be allowed to use the tool
without supervision or instruction by a person
responsible for their safety.
Ensure children do not play with the device.
RISK OF INJURY! Before
performing maintenance tasks, disconnect the
compressed air supply.
EXPLOSION HAZARD! Never
use petrol or other flammable liquids
to clean the air tool! Sparks could
ignite residual vapours inside the compressed
air unit resulting in the compressed air unit ex-
ploding. Do not use the device in explosive en-
vironments with flammable liquids, gasses or dust.
Never work on materials which are or could
potentially be highly flammable or explosive.
Only use the equipment in areas of application
for which it was designed!
Do not overburden the device.
Never use hydrogen, oxygen, carbon
dioxide or other bottled gasses to
power this tool as doing so may re-
sult in an explosion and thus may cause severe
injuries.
Regularly maintain and clean the device as
specified (see chapters „Maintenance" and
„Cleaning and care").
Inspect the device for any damage before use.
Always make sure that the device is in perfect
condition each time before use.
Always be attentive! Unexpected movement of
the device may cause hazards.
Avoid placing your body in an unnatural position.
Keep proper footing and balance at all times.
By doing this you will be in a better position to
control the compressed air unit in unforeseen
circumstances.
GB
7
28.05.14 11:15