Herunterladen Inhalt Inhalt Diese Seite drucken

Master WDM 61 Bedienungsanleitung Seite 17

Vorschau ausblenden Andere Handbücher für WDM 61:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
WDM 61.book Seite 17 Mittwoch, 28. Mai 2008 8:08 08
Pythagoras I – Determining
a Distance with 2 Auxiliary
Measurements
– Press the
button 3x briefly until the
symbol appears on the display. The laser is
activated.
– Aim at the upper measuring point and initi-
ate measurement 1 by pressing button
– Hold the unit as horizontal as possible. To
initiate continuous measuring, press and
hold button
. When the rapid beep
sounds, circle generously around measuring
point 2. Press button
ment.
The auxiliary measurements and result l are
indicated in the display.
Pythagoras II – Determining
a Distance with 3 Auxiliary
Measurements
– Press the
button 4x briefly until the
symbol appears on the display. The laser is
activated.
– Aim at the upper measuring point and initi-
ate measurement 1 by pressing button
– Hold the unit as horizontal as possible. To
initiate continuous measuring, press and
hold button
. When the rapid beep
sounds, circle generously around measuring
point 2. Press button
ment.
– Aim at the bottom measuring point and initi-
ate measurement 3 by pressing button
The auxiliary measurements and result l are
indicated in the display.
Mark-out Function
D
For uniform marking-out of distances, a clear-
ance can be entered. In the following measure-
ment, the currently measured distance is com-
pared with the entered value and the difference
is shown on the display.
– Press the
button 5x briefly. The
mark-out function symbol
and the preset value 1,000 appear
on the display.
– Adapt the measure to the required value with
– Press the
– Align the laser beam and move the device
– When the acoustic signal changes and
.
– Move the device further in the same direc-
to end the measure-
Automatic Release (Timer)
The automatic release can be used when meas-
uring and holding the target plate at the same
time is required.
– Press the
– By pressing buttons
The countdown starts immediately after releas-
ing the button or, when the laser was not acti-
vated, after pressing button
.
Each of the last 5 seconds is indicated acousti-
cally.
to end the measure-
.
the
buttons. The preset value
appears in the intermediate line.
button to switch on the laser.
while watching the display.
0,000 is indicated, the measuring value at
the rear stop/rest corresponds with measure.
Mark this point.
tion. The next multiple of the preset value
appears in the intermediate line.
button briefly to initiate a
5 second countdown. The symbol appears
on the display.
can be prolonged to 60 seconds.
, the countdown
.
17

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis