Measuring Procedure
DANGER: Do not point the laser beam at
other persons or animals!
Length Measurement
Switch on the laser with the
Align the laser point onto the target and actuate
a length measurement by once more briefly
pressing the
pushbutton. The measured
length is indicated in the display.
The laser automatically switches off
60 seconds after the last pushbutton actu-
ation.
NOTE: Measurement errors can occur on the
following surfaces: Transparent liquids, glass,
Styrofoam, semipermeable surfaces, glossy sur-
faces. Measurements on dark and matt surfaces
lead to increased measuring periods.
Tracking
C
D
Tracking is suitable for determining the diago-
nal within a space
length) or the right-angled length onto a wall
(shortest determined length). It is also suitable
for marking out distances
Switch on the laser with the
Align the laser point onto the target and actuate
the continuous measurement by once more
pressing the
pushbutton for a longer
period. During the measurement, the laser point
must be moved over the target.
A fast beeping tone sounds during the measur-
ing.
End the measurement by pressing the
button. The greatest, the shortest and the last
measured distance are indicated in the display
Addition/Subtraction
– Measure a distance.
– Press button
or
– Measure a 2. distance.
The two measured values and the result are indi-
cated.
Pressing the
button 1x briefly resets the last
step.
16
pushbutton.
(greatest determined
.
pushbutton.
push-
.
Area Measurement
– Press the
button 1x briefly.
The area symbol
appears on the display
and the laser is activated.
– Press pushbutton
and take the first length
measurement (e. g. length).
– Press pushbutton
length measurement (e. g. width).
The two measured values and the resulting area
are indicated in the display.
The area measure is correct only when
the measurements have been taken at a
right angle to each other.
Volume Measurement
– Press the
button 2x briefly.
The volume symbol
play and the laser is switched on.
– Press pushbutton
and take the first length
measurement (e. g. length).
– Press pushbutton
length measurement (e. g. width). The area
measure appears on the display!
– Press pushbutton
length measurement (e. g. height).
The three measured values and the resulting vol-
ume are indicated in the display.
The volume measure is correct only when
the measurements have been taken at a
right angle to each other.
Measurement using the Pythagoras
Theorem
E
The device can determine a distance based on
auxiliary measurements in accordance with the
mathematical Pythagoras' theorem. This is use-
ful when a direct measurement cannot be taken.
The measured points must be in one line.
The measuring sequence shown in figures
must be adhered to.
Best results are achieved when the device is
turned around a firm point. As an example,
place the device against a wall and turn it
around the completely folded out stop/rest
angle.
Use the tracking function to determine the small-
est distance rectangular to the target and the
greatest distance for the other measurements.
The automatic release/timer can be used.
and take the second
appears on the dis-
and take the second
and take the third