Mounting and Connection Instructions mifare/DESFire EV1 reader "Accentic" with/without keypad
28
7.
Stand alone programming mode
To program in this mode, only the operating voltage is required.
Please note!
The settings of the parameters can be modified via the RS-485 interface of a connected
controller.
It is not possible to make any changes of the parameters via Clock/Data (as it is only
unidirectional). In this case it is necessary to make a "stand alone" programming.
7.1
Activate programming mode
Press the 3 keys (with the symbols as shown) simultaneously and keep
pressed.
Apply the operating voltage. As soon as the programming mode is
activated, the three LEDs flash every second. Release keys.
7.2
Clear address
Activate
1
to clear an already allocated address.
7.3
Load standard values
Activate
2
to create the condition on delivery.
-
Illumination: deactivated for the non load status
An already allocated address is not altered.
7.4
Keypad lighting
If you require permanent illumination, the brightness for the no-load status can be set in steps
using button "4" and "5".
4
Key "4":
Every time the button is activated, the illumination becomes gradually darker until
it is fully switched off.
Key "5":
The brightness increases in steps until it reaches maximum brightness.
5
The set value is permanently saved when the programming mode is exited.
7.5
Exit programming mode
Áctivate
X
key.
(only readers with keypad)
i