Herunterladen Inhalt Inhalt Diese Seite drucken

Synchronization; Start-Up And Configuration; Important Informations About Usage Of Data Carriers - Honeywell mifare-Leser "Accentic" Anleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Mounting and Connection Instructions mifare/DESFire EV1 reader "Accentic" with/without keypad
5.2

Synchronization

In order to prevent densely packed readers from affecting one another, they must be connected to
one another via the "Synchronization" line (black). Up to 4 readers can be synchronized in this
manner (irrespective of the used interface).
Synchronization is required at a distance of £
The data carrier that is identified first has priority during the read process. The other readers
involved are inactive. After a period of 5 sec. they are reactivated.
Reader 1
black
Synchronization line
6.

Start-up and configuration

6.1

Important informations about usage of data carriers

X
Reader 2
black
The data carrier should be held approximately in the middle of this field.
Ensure that the desired data carrier is held separately in the
reading range.
In order to achieve a greater transmission range when using the data carrier, a
relatively high current is required during transmission (<55 mA).
Without data carrier transmission the reader automatically switches from active
mode to low current mode and thus reduces the current consumption on
average to <30 mA.
1 m
(approximate value).
Reader 3
black