Installation example
1 Truma electric boiler
2 Control panel
3 Safety/drain valve
Important operating notes
Repair jobs are only to
be carried out by an
expert!
1. Any alteration to the appli-
ance or the use of spare parts
and accessories which are
important for the functioning
of the heater and which are
not original Truma parts, as
well as the non-observance
of the installation and operat-
ing instructions, shall lead to
the cancelling of the guaran-
tee and exclusion of liability
claims. It also becomes illegal
to use the appliance, and
in some countries this even
makes it illegal to use the
vehicle.
2. If just the cold water sys-
tem is being used, without
water heater, the heater tank
is also filled up with water.
In order to avoid damage
through frost, the water con-
tents must be drained by ac-
tuating the safety/drain valve,
also when the heater has not
been used. As an alternative,
two shutoff valves, resistant
to hot water, can be fitted in
front of the cold and hot
water connection.
4
3. When connecting to a
central water supply (rural or
city mains), a pressure reduc-
tion valve must always be
installed to prevent pressures
above 2.8 bar from develop-
ing in the water heater.
In the event of malfunctions
please always contact the
Truma Service division
(cf. page 16).
The installer or vehicle owner
must apply the yellow sticker
with the warning information,
which is enclosed with the
appliance, to a place in the ve-
hicle where it is clearly visi ble
to all users (e.g. on the ward-
robe door)! Ask Truma to send
you stickers, if necessary.
Electric boiler
Electric hot water heater 230 V, 850 W
Maintenance
The water container
used is made of VA
stainless steel, which is food-
stuff-compatible.
Use wine vinegar for de-scal-
ing the water heater, this
being introduced into the ap-
pliance via the water supply.
Allow the product to react
and then thoroughly flush
out the appliance with plenty
of fresh water. To sterilise
the water we recommend
„Certisil-Argento". Other
products, particularly those
containing chlorine are
unsuitable.
To avoid infestation by micro-
organisms, the boiler must
be heated to 70°C at regular
intervals.
Do not use the water as
drinking water!
Technical data
determined in accordance
with Truma test conditions
Power supply:
230 V ~, 50 Hz
Power consumption:
850 Watt (3,7 A)
Water contents:
14 litres
Heating time from approx.
15°C to approx. 70°C:
approx. 70 Min.
Thermal cut-out:
70°C
Over-temperature
protection:
90°C
Water pressure:
up to max. 2.8 bar
Weight (without contents):
approx. 3 kg
Dimensions:
height: 295 cm,
width: 405 cm
Conformity Declaration:
The Truma electric boiler
complies with the require-
ments of EN 60335, EMC
directive 89/336/EEC, low
voltage directive 73/23/EEC
and the associated standards
and technical specifications,
and is therefore entitled to
bear the CE symbol.
The right to effect technical
modifications is reserved!