4 - INSTRUCTIONS FOR USE

EN

4.1 FIRST USE

The pump is delivered with the battery in stand-by so that it cannot be switched on accidentally. In this condition the pump will not start even if
the start button is pressed. For the battery to work, carry out the following:
1. Connect the power unit to the pump and plug it into the power socket.
2. The blue light will start flashing indicating that the battery is charging.
3. Leave the battery charging for at least 4 hours. The blue light will stop flashing when charging is
complete.
4. After charging, the pump can be used either connected to the mains through the appropriate power
B
unit or disconnected and therefore battery-operated.
5. The battery provides approx. 25 minutes of continuous operation, at which point it must be recharged.
The flashing blue light shows the battery is low; the light stays on for 2 minutes when the pump is
inactive.
A
C
A PUMP
B MANUAL PUMP START BUTTON
C VACUUM NOZZLE
12
Battery status
Vacuum
indicator
indicator
A flashing blue
A red light
light indicates a
indicates the end
discharged battery
of the vacuuming
process
4.2 VACSY® VALVE
Place the food into the container, and close it with the VacSy® lid. Turn the rotation disk to the VACUUM position. Insert the VacSy® Vacuum
Nozzle into the valve and extract the air. When the red light comes on, the vacuum has been created. Remove the Pump and turn the valve to
the CLOSE position. The container is now airtight. To open the container, turn the valve to the OPEN position. Now you can open the container.
C
E
A
D
B
A. VALVE
B. VACUUM
G
C. OPEN
D. CLOSED
E. MONTH INDICATOR
F
F. DAY INDICATOR
G. ROTATION DISK