GB
container (5).
2. Secure the feet with the Philips
head screws supplied.
3. Place the motor housing (3) on
top of the collector (5) and close
it with the clip.
4. Lightly squeeze together the
ends of the retaining bracket
(25) and click it into the motor
housing (3).
5. Installing the accessories:
- Attach the vacuum hose (18).
- Fit the handle with air control
(15).
- Install the telescopic suction
tube (16). (Press the button on
the telescopic suction pipe to-
wards
desired length).
- Install the nozzle desired (
21/22/23/24).
Never vacuum without a
filter!
Operation
Fully unwind the suction hose (
18) before commencing work.
Switching on/off
Connect the mains plug.
To vacuum dust, plug the electrical
tool onto the mains socket on the
vacuum (
Only connect electrical appliances
with a maximum power rating of
2200 W.
Switching on the vacuum cleaner
(Permanent operation):
Move the On/Off switch (
position.
10
and pull out to the
9).
10) to the "I"
Switch on electrical appliance +
vacuum cleaner:
1. Move the On/Off switch
10) to the position
(
2. Switch on electrical appliance.
Switching on the electrical appli-
ance automatically switches on the
vacuum cleaner. Once the electrical
appliance has been switched off,
the vacuum cleaner switches off fol-
lowing a time lapse.
Switching off the vacuum cleaner:
Move the On/Off switch (
"0" position.
Work breaks
To store the assembled suction set during
a work break, the telescopic suction tube
(16) can be pushed
together and the suction tube holder
(17) plugged into the socket on the mo-
tor head (3);
Place the telescopic suction tube (16)
in the retaining bracket (25).
Dry vacuuming
The appliance is supplied with the
fluted filter (11) fitted.
Vacuuming with a fluted filter:
1. To vacuum dry, fit the fluted filter (11a)
onto the filter cage on the motor hous-
ing (3). Here, the upward curved seal-
ing lip must point away from the motor
housing.
2. Fit the filter cover (11b) and turn it gen-
tly to lock it:
10) to the