Measurements
3.4 Resistance/ continuity testing
Set function
d
Connection diagram
LowΩ (testing current: ≥ 200 mA)
e
Press the
f
View results
Displayed results:
R: M ain LowΩ resistance result
R+: L owΩ resistance sub-result with positive
voltage at L terminal
R-: L owΩ resistance sub-result with positive
voltage at N terminal
b
Select
sub-function
- LowΩ (RLOW)
- Continuity
- B efore performing LowΩ
measurement compen-
sate test leads resistance,
if nec. (see instruction
manual)!
Press the
key
Press the
Resistance/ continuity testing
c
Set parameters and limits
- High limit resistance
[*Ω sets limit off,
0.1 Ω - 20.0 Ω]
Continuity (testing current: max. 8.5 mA)
key to start.
key again to stop measurement.
Displayed results:
R:
Continuity resistance