battery is charged at a constant current until it reaches the final charge voltage. The charge current is then slowly reduced until the pack is full. By its
nature this method charges about 70 - 80% of the pack's capacity relatively quickly, but the final 20 - 30% takes disproportionately longer owing to the
lower current. The capacity limit TCS CAPACITY (10 - 100%; default setting 100%) generates an audible alert at the selected percentage; the charger
then responds by continuing or halting the charge, as programmed under the following point TCS END ACT. If a capacity of 70 - 80% is sufficient for your
purposes, you can halt the charge process at that point, and enjoy much shorter charge times.
TCS response TCS END ACTION
The capacity limit TCS CAPACITY emits an audible alert when the programmed percentage is reached, while the TCS response defines how the charger
reacts: continue charging or stop the charge process.
Continue charging (CONTI.): the alert is generated at the programmed percentage, but charging continues thereafter.
Stop (STOP): charging stops.
The following screen displays appear if you select the battery type NiXX.
The screen shows a maximum of four lines; pages 2 and 3 appear when
you move the Select arrow further down.
Cycle mode CYCLE
Cycle mode provides a means of charging and discharging a battery in
(multiple) cycles, e.g. in order to restore the pack's normal performance
more quickly after a protracted period of storage.
Move the Select arrow to the CYCLE line, then press ENTER. The cycle
can commence with a charge (C→D) or a discharge (D→C) process; use the INC or DEC button to select your preferred sequence, then press ENTER
again. The cursor now moves to the number of cycles, where you can select any number in the range 1 to 10 cycles. Pressing ENTER causes the cursor
to move to the interval time (1 - 30 minutes), where you can enter the interval between the charge and discharge phases.
Note: Cycle mode uses the automatic charge and discharge modes, i.e. at this point you cannot pre-select any charge or discharge currents.
With the Select arrow at the Cycle mode line (CYCLE), start the process by holding the ENTER button pressed in for two seconds.
Charge CHG
The Charge line (CHG) displays the charge current and the ∆ peak voltage per cell. These parameters can be selected with the ENTER button, and
altered using INC or DEC. The charge current is limited to 1C by default, i.e. if you enter 2200 mAh under battery capacity in the charge memory, the
charge current is automatically set to 2.2 A. The charge current can be set to any value in the range 0.1 to 20 A, taking the maximum charge power into
account. Depending on the power supply, the unit may be unable to charge at the selected current, i.e. the maximum possible current may not be used
for charging. If this should occur, the screen displays the charge current actually in use.
46
14. NiXX charge program
Charge
Cycle
Max. capacity in x%
→ end of charge
Trickle charge current
Safety timer
11] NiMH
6S
3300mAh
Page 1
CYCLE :
C->D
1x 10m
CHG.
3 . 3 A
5mV/C
:
DCHG. :
3.3A
0.8V/C
Cut-off temperature
Page 2
CUT.TEMPER. :
55°C
MAX.CAPACITY:
150%
∆peak detection dis-
PEAK DELAY
:
3min
abled for x minutes
TRI CURRENT :
100mA
Page 3
SAFETY TIMER: 120min
Operating Manual ULTRA DUO PLUS 80