If you are using controllers with this occupation, you can connect the DMX-output of the controller directly
with the DMX-input of the first fixture in the DMX-chain. If you wish to connect DMX-controllers with other
XLR-outputs, you need to use adapter-cables.
Building a serial DMX-chain:
Connect the DMX-output of the first fixture in the DMX-chain with the DMX-input of the next fixture. Always
connect one output with the input of the next fixture until all fixtures are connected.
Caution: At the last fixture, the DMX-cable has to be terminated with a terminator. Solder a 120
between Signal (–) and Signal (+) into a 3-pin XLR-plug and plug it in the DMX-output of the last fixture.
Connection with the mains
Connect the device to the mains with the power-plug.
The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Lighting effects must not be connected to dimming-packs.
OPERATION
Before starting operation make sure that the cloth cannot be drawn into the intake of the ventilation fan.
After you connected the effect to the mains, the AC-300 DMX LED/RGB Air Effect starts running.
Sound Control
In order to select Sound Control, first set dipswitch 10 to ON and dipswitch 9 to OFF. Sensitivity can be
adjusted with the rotary-control.
Manual Mode
To select Manual Mode set dipswitches 8, 9 and 10 to ON.
Dipswitch 1 and 2 control the brightness of the „R" LEDs.
Dipswitch 3 and 4 control the brightness of the „G" LEDs.
Dipswitch 5 and 6 control the brightness of the „B" LEDs.
International
L
N
19/41
resistor
00026128.DOC, Version 1.4