D.2 Data to Pluto
Modbus TCP slave address 1, (0x01), for read/write data to Pluto system.
Note: This data is common for all connected clients. E.g. valid data
Address
Data Name
0
Length [13, 0x000D]
1
Area valid bit information
(0=Invalid, 1=Valid)
bit 0, valid data for area 0
-
bit 1, valid data for area 1
-
bit 2, valid data for area 2
-
bit 3, valid data for area 3
-
2
Area 0, Bits
3
Area 0, Register 0
4
Area 0, Register 1
5
Area 1, Bits
6
Area 1, Register 0
7
Area 1, Register 1
8
Area 2, Bits
9
Area 2, Register 0
10
Area 2, Register 1
11
Area 3, Bits
12
Area 3, Register 0
13
Area 3, Register 1
D.3 Gateway Configuration
Modbus TCP slave address 4, (0x04), to write new configuration to the gateway.
Note: This data is common for all connected clients. E.g. valid
configuration will be the data written by the last client writing
data to this slave address.
Note: For additional data Pluto number and IO-type shall be set to
zero if data area is not used.
to Pluto will be the data written by the last client writing data
to this slave address.
Data Type
UINT
UINT
UINT
UINT
UINT
UINT
UINT
UINT
UINT
UINT
UINT
UINT
UINT
UINT
129