05.2006
X18 – Fan supply
NOTE
The 1AC 230 V fan supply X18/1 must be grounded (neutral conductor
N connected to protective conductor PE).
7.5
Fan fuses
Table 7-10
NOTE
The 230 V fan must be supplied with AC 230 V externally via terminal
strip X18 1/5 on the PSU.
Siemens AG
6SE7087-6JK50
SIMOVERT MASTERDRIVES
Terminal Designation
1
N
2
-
3
Assigned internally
4
-
5
L
6
-
7
Assigned internally
8
-
9
-
10
Assigned internally
11
Assigned internally
12
Assigned internally
13
Assigned internally
Line voltage AC 380 V to 480 V
Order number
Fan fuse
(F1 / F2)
6SE7031-0EE 0
FNQ-R-6/10
6SE7031-2EF 0
FNQ-R-2
6SE7031-5EF 0
FNQ-R-2
6SE7031-8EF 0
FNQ-R-2
6SE7032-1EG 0
ATDR 2 1/2
6SE7032-6EG 0
ATDR 2 1/2
6SE7033-2EG 0
FNQ-R-5
6SE7033-7EG 0
FNQ-R-5
6SE7035-1EK 0
Manufacturer:
FNQ-R
ATDR
= 5 corresponds to MASTERDRIVES Motion Control
= 7 corresponds to MASTERDRIVES Motion Control Performance 2
Fan fuses
Operating Instructions
Meaning
Fan supply (neutral conductor)
Fan N via fuse F1
Fan supply (phase)
Fan L via fuse F2
Fan fuse
(F3 / F4)
FNQ-R-4
Bussmann
Gould Shawmut
Connecting-up
Range
230 V ± 15 % /
50/60 Hz
Fan fuse
(F101 / F102)
FNQ-R-5
7-19