Herunterladen Inhalt Inhalt Diese Seite drucken

Water Connection; Power Connection - Kärcher HDS-E 8/16-4M 12kW Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für HDS-E 8/16-4M 12kW:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Adjusting the dosage of the system
care Advance RM 110/RM 111
 Determining the hardness of tap water:
through the public water supply works,
using a hardness tester (order no.
6.768-004)
Water hard-
Scale on the system care
ness (°dH)
service switch
<3
OFF (no dosing)
3...7
1
7...14
2
14...21
3
>21
4
 Set the service switch according to the
water hardness in the table.
Note: Observe the following when using
system care Advance 2 RM 111:
Calcification protection: See table
Pump care: Set the service switch to at
least setting 3.
Refill detergent
Caution
Risk of injury!
Use Kärcher products only.
Under no circumstances fill solvents
(petrol, aceton, diluting agent etc.)
Avoid eye and skin contact.
Observe safety and handling instruc-
tions by the detergent manufacturer.
Kärcher offers an individual cleaning
and care appliances program.
Your dealer will consult you gladly.
 Refill detergent.
Install the hand-spray gun, the jet
pipe, the nozzle and the high
Figure 4
 Connect ray tube with hand spray gun
 Tighten the screw connection of the
spray lance fingertight.
 Insert high pressure nozzle into cover-
ing nut
 Install covering nut and tighten firmly
 Connect the high pressure hose to the
high pressure connection point of the
machine.
Installing spare high pressure hose
Figure 5

Water connection

For connection values refer to technical
specifications
 Connect the supply hose (minimum
length 7.5 m, minimum diameter 3/4") to
the water connection point of the ma-
chine and at the water supply point (for
e.g. a tap).
Note: The supply hose is not included.

Power connection

For connection values, see technical
data and type plate.
The electrical connections must be
done by an electrician according to IEC
60364-1.
The voltage indicated on the type plate
must correspond to the voltage of the
electrical source.
The installation of the electrical plug
may only be performed by the author-
ised customer service/electrician. The
electrical plug is not included.
Danger
Danger of injury by electric shock.
Unsuitable extension cables can be
hazardous. Only use extension cables
outdoors which have been approved for
this purpose and labelled with a suffi-
cient cable cross section:
– 4
EN
pressure hose