Quick Start Guide
MA504/1
Electronic display
For detailed documentation please refer under
http://www.siko-global.com/p/ma504-1
General information
Prior to installation, including in hazard areas, read the Installation instruc-
tion (download from the internet). It contains the safety instructions, hints
and technical data to be observed during installation. Subject to change with-
out notice.
Caution
In order to ensure reliable functioning of this product, take care to transport,
store, position and mount it appropriately. Exercise care when you operate and
maintain the device. Only properly qualified personnel is authorized to install
and operate this product.
Safety information
It is important for safety reasons that you read and understand the below
instructions before you install the system:
• Installation, connection, commissioning and maintenance shall be done by
properly qualified personnel.
• It is the responsibility of the customer to ensure that the personnel con-
cerned read and follow the instructions and directions of this Guide and of
the Installation instruction.
• It is the responsibility of the customer to ensure that the electronic display
is correctly connected and configured.
• Only personnel specifically trained by SIKO shall execute repair and mainte-
nance work.
SIKO GmbH
Weihermattenweg 2
Phone: + 49 7661 394-0
79256 Buchenbach
Fax: + 49 7661 394-388
www.siko-global.com
Service: support@siko.de
MA504/1 · Date 10.05.2016 · Art. No. 88541 · Mod. status 242/15
Mounting of the electronic display
For panel mounting we recommend dimensions 67
+3
• Panel
must be provided with cutout for MA504/1.
1
• Push the display into the panel cutout until the mounting tabs snap com-
pletely.
• Mounting tabs hold the unit, but allow easy removal, too.
Electrical Installation
The location should be selected to ensure that no capacitive or inductive inter-
ferences can affect the electronic display or the connection lines!
• When mounting the system keep a maximum possible distance from lines
loaded with interference. Use screening shields or metallized housings.
Connection sensor
Connect the sensor to the MA504/1 via the 8-pin jack. Sensor mounting as well
as laying of the sensor cable are described in the User Information for the sen-
sor MS500H.
Connection of power supply
Battery powered.
sensor connection
battery case
Technical data
Electrical data
Additional information
Operating voltage
3 V DC
Current consumption ~150 µA
at 3 V DC
mm x 33.5
+0.3