6. ELECTRONIC BOARD

DISPLAY
+
LED
FCA
J2
FCC
ENCODER
J5
J3
LIMITS
ENCODER
KEY:
J1
Terminal board for accessories
J2
Connector for receiver
J3
Rapid connector for encoder
J4
Rapid connector for start-up capacitor
J5
Rapid connector for the magnetic limit switch sensor
J6
Terminal board for motor and flashing light
J7
Terminal board for main power supply
F1
Fuse for main power supply
F2
Fuse for accessories power supply
 9 Technical Data
Mains power supply
Max power
Max. motor power
"
Max. accessories load 24 V
F1
F2
Ambient operating temperature
Flashing Light
PowerSlide
-
F
OPEN
FSW
STOP
OP
B
EDGE
OPEN
FSW
SAFE
A
CL
J1
1 2 3 4 5 6 7 8 9 10 11 12
24 V "
500 mA
max
SPRINT 382 (230 V~)
230 V~ (+6%...-10%) 50 Hz
10 W
1000 W
500 mA
5 A
800 mA
-20 °C - +55 °C
230 V~ - 60 W
F2
J6
13 14
CAP
LED:
FCA
Limit switch
FCC
Limit switch
OPEN B
Partial opening command
OPEN A
Total opening command
FSW OP
Opening photocells
FSW CL
Closing photocells
STOP
Automation stop
EDGE SAFE N.C. contact for sensitive edges
ENCODER
Incremental encoder
17
F1
J4
J7
15
16
17
PE N L
M
6 A
60 W max
N L
 2 8