1. Scope of delivery

Depends on order, consisting of shell
i
kit, final assembly set, room air
control and/or accessories.

1.1 WRG 35-SR Shell kit

Article no. 0192.0450
● Wall sleeve (3-part):
● Plaster protective cover (2 pieces)
● Polystyrene support with surface for a
spirit level
● Drilling template
● Drip tray
● Stainless steel external cover with
4 cover plugs
● Mounting and Operating Instructions

1.2 WRG 35-1-SE Final assembly set

Article no. 0082.0235
● Complete fan unit, consisting of:
in each case 2 of: housing shells, fans,
electrically operated shutters,
fly screens, G4 air filters.
in each case 1 of: plate heat exchanger,
control circuit board and pluggable terminal
block for the power connection.
● Internal cover
● Foam seal
● Mounting and Operating Instructions
1.3 WRG 35H-SE Final assembly set
with hygrostat, Article no. 0082.0234
● Complete fan unit, consisting of :
in each case 2 of: housing shells, fans,
electrically operated shutters,
fly screens, G4 air filters.
in each case 1 of: plate heat exchanger,
control circuit board with humidity control
and pluggable terminal block for the power
connection.
● Internal cover
● Foam seal
● Mounting and Operating Instructions
1.4 RLS 4-1 AP / RLS 4-1 UP
Room air control
Article no. 0157.0847 / 0157.0848
● Room air control for WRG 35-1
(not permitted for WRG 35H)
● RLS 4-1 AP: Surface-mounted room air
control
● RLS 4-1 UP: Recessed-mounted room air
control
● Control cable, 5 m long, ready-made, incl.
RJ12 Western plug
1.5 RLS 5 AP / RLS 5 UP
Room air control
Article no. 0157.0845 / 0157.0846
● Room air control for WRG 35-1 or
WRG 35H
● RLS 5 AP: Surface-mounted room air
control
● RLS 5 UP: Recessed-mounted room air
control
● Control cable, 5 m long, ready-made,
incl. RJ12 Western plug

1.6 Special accessories

● WRG 35-VH Extension sleeve
(Article no. 0092.0451)
To extend the wall sleeve. With 1-part wall
sleeve, 2 separating bridges and conden-
sation hose extension.
● WRG 35-AR Stainless steel compensating
frame (Article no. 0092.0454)
For compensating for wall thicknesses
251 to 350 mm. With 1-part wall sleeve,
2 separating bridges condensation hose
extension and 4 stainless steel fixing
screws.
● Junction box WRG 35-AAD (Article no.
0092.0501) for TAK control cable, with
3 RJ12 sockets
● WRG 35-TAK 5 Control cable (5 m long)
with 2 RJ12 plugs (Article no. 0092.0502)
● WRG 35-TAK 10 Control cable (10 m long)
with 2 RJ12 plugs (Article no. 0092.0503)