Electrical connection

The electrical connection must be carried out by a qualified electrician who is able to calculate
exactly the required wire cross-section and capacity of the workshop fuses.
Check that the mains voltage of the machine corresponds with the voltage supply to your workshop.
Now remove the electrical connection box and introduce the cable. Connect the 3 phases to the
terminals on the connection block marked L1, L2, L3. If there is a neutral conductor (blue) it must
be connected to the terminal N.
Connect the earth wire (green-yellow) to the terminal marked with the earth symbol PE.
Attention : Check first if the saw spindle runs freely and if all safety devices are fitted before starting
the machine.
If the direction of rotation of the sawblade is not correct, the wires L1 and L2 must be exchanged
(clockwise direction of the spindle is correct).
For safety reasons this must only be done without the sawblade on the spindle !
Thermal overloads
The machine has overload protections on both saw and scoring motors. Should the motor be shut-off
by one of these protectors, it is necessary to wait a few minutes untill the overload has cooled down.