1. Screw the hose [4] onto the shut-off valve [3] and fix the cap nut [7] (Fig. 2)
2. Screw the spray wand [6] onto the shut-off valve [3] (Fig. 2)
Checks
Visual inspection:
sure gauge [16] and spray wand [6] undamaged? (Figs. 1, 10)
+
Pay special attention to the connections between the tank – hose and hose – shut-
off valve and to the condition of the pump thread and hose.
No leaks:
Pump up the empty device to 2 bar.
The pressure must not decrease more than 0.5 bar within 30 minutes.
Function:
Pull the red button on the safety valve [13]. (Fig. 3)
The pressure must dissipate.
Activate the shut-off valve [3] (Fig. 11)
The shut-off valve must open and close.
Making preparations
Observe the instructions in the section entitled „Safety".
1. Pull the red button on the safety valve [13] until the tank is depressurised. (Fig. 3)
2. Press the pump handle [14] down and turn it counterclockwise.
The pump handle is locked in place. (Fig. 4)
3. Unscrew the pump [2] from the tank [2]. (Fig. 5)
+
To ensure the pump remains clean during storage, we recommend you attach the
pump to the pump holder [15]. (Fig. 6)
+
We recommend you mix the spraying liquid in the device or premix it in an external
tank: Fill to 1/3 with water, pour in the spraying agent, and then add more water until
full.
4. Add the spraying liquid to the tank [1] (Fig. 6)
5. Screw the pump [2] into the tank [1]. (Fig. 7)
6. Swivel in the pump holder [15]. (Fig. 7)
With pump
7. Press the pump handle [14] down and turn it counterclockwise.
The pump handle is unlocked. (Fig. 8)
8. Generate the required pressure (→ Table 2) in the tank [1]. (Fig. 9).
+
The maximum pressure should not exceed 6 bar (red line on the pressure gauge
[16], Fig. 9). If the maximum pressure is exceeded, the safety valve will engage and
release the excess pressure.
9. Press the pump handle [14] down and turn it counterclockwise.
The pump handle is locked in place. (Fig. 4)