Switching ON

To turn on the device pull the ON/OFF switch (1) to the position I or II.
To turn off the device push back the switch (1) to the position 0.

How to install the Nozzle

The nozzle can be pushed over the hot air nozzle. Turn the nozzle to
lock it with the bayonet lock.
Do not touch the nozzle during or immediately after use of the device.
The nozzle is very hot.

Mounting the Extension Handle

The extension handle contains for two parts. Fasten both parts
together and attach the extension handle to the device. Make sure that
the extension handle firmly clicks into position.
Always operate the device with the extension handle.

Operation

1. Ensure the extension handle is firmly fixed onto the device and that
the device is turned off.
2. Install the nozzle (9). Insert the plug into the socket.
3. Make sure the nozzle is not blocked before turning the device on.
Set the temperature to the setting II. Allow the device about 45
seconds to warm up.
4. To eliminate weeds, hold the nozzle over the weeds for about
5 seconds. During this time the cell structure of the weed is de-
stroyed. As a result, the weed dies within a few days.
It is not necessary to completely burn the weeds, 5 seconds is
more than sufficient.
For an efficient treatment the nozzle should be held around 0 to
5 cm above the weeds.
The effects are not visible immediately but will take a while before
they can be seen. It is more of a long-term effect.